manufacturers

INTACT Bike Power GEL battery YTR4A-BS

INTACT Bike Power GEL battery YTR4A-BS
  60+ sold
31,04 EUR Out of stock
incl. 19 % Tax excl. Shipping costs
Out Of Stock
Product No.:

299-203

EAN:

4250227524360

Manufacturer:

INTACT

Manufacturer Nr:

299-203

Shipping time:
on request on request (international delivery is divergent)
Availability:
out of stock

INTACT Bike Power GEL battery YTR4A-BS

Bike Power GEL battery YTR4A-BS

Intact Bike Power Battery GEL YTR4A-BS

Width x Depth x Height = 113 x 48 x 85 mm
Cold start current: 60 A (DIN)

Our absolute top product for motorcycle batteries is the intAct Bike-Power Gel series.

This series was specially developed for modern motorcycles with various electrical consumers and ABS. By combining the fleece separators and the fixed electrolyte in gel, up to 30 % more power is achieved compared to conventional motorcycle batteries. The batteries also impress with very low self-discharge and very high vibration resistance.


br/>Information about treatment and maintenance of your battery

A battery is only an energy storage device and any energy removed must be returned to it immediately 100% by the generator of the vehicle or externally by a charger, if the energy balance is rather negative due to short-term use or due to generally few use times with longer stance phases.

To ensure a long battery life, you should observe the following:
- Use of the battery only for its intended purpose (starter batteries for starting and operating a vehicle with internal combustion engine).
- The surface of the battery must be kept clean and dry, no oils or liquids must be deposited on it to avoid the formation of leakage currents which can cause considerable self-discharge.
- If possible, check battery level at least every 6 months and top up with purified water if necessary (do not top up with accumulator acid).
- In case of high water loss, please have the function of the charge controller checked by a specialist. With an optimal installation location and normal requirements, your battery will consume little to no water, but these factors are very different depending on use.

If your vehicle tends to have a negative energy balance due to use (short distances - longer stance phases - high comfort equipment - start-stop operation), the battery charge state should be checked at necessary intervals (2 - 3 months).

In order to always have sufficient starting safety and not to cause any damage to the battery, it should always be charged at least 75%. This can be determined with the open-circuit voltage or with an acid lifter.
Normal voltage:
12.51 V - 12.57 V = 75 % charged
12.69 V - 12.75 V = 100 % charged

Acid density:
1.25 kg/l = 75 % charged
1.28 kg/l = 100 % charged

This state of charge should at least have the battery, even if it still works with less, but this is still due to its durability.

Optimal would be 100 % charge - for 100 % use!

Since today's vehicle generation places a considerably higher electrical demand on the battery (due to its extensive comfort and electronic equipment), even newer vehicles can quickly lead to a negative energy balance. If most of the energy generated is required by the on-board power supply and the remaining energy is no longer sufficient to fully charge the battery.

For vehicles that are only used seasonally (convertibles, motorcycles, tractors, harvesting vehicles, construction machinery and construction vehicles), the same charge requirements must be observed for the battery as described above.

Check the charge (open-circuit voltage) of your battery every 2 months at the latest and recharge it if necessary. Due to the continuous chemical process, every battery is subject to self-discharge, which inevitably leads to the deepest discharge of your battery if this is not compensated by charging. If this is still connected to the vehicle, the discharge may be even faster, as the vehicle may also consume a standby current. It is best to disconnect the battery.

deep discharge is not a warranty but always self-inflicted and usually associated with the total failure of the battery.

The ideal temperature to store a battery over a stance phase is 10 - 15 degrees. Higher temperatures accelerate self-discharge and the loss of water.

Eternal life the battery does not have nevertheless - the capacity is exhausted sometime.
Always full charge + normal load = slow reduction of capacity.
Insufficient load + high load = rapid reduction of capacity.

Technical data

Artikel:PW-299-203
EAN:4250227524360
Manufacturer:intAct
Execution:wartungsfrei
Category:Gel Batterien
Weight:1.0000
Depth:48.00 mm


Customers who bought this product bought the following products also
Batteriepfand

Pfand

Batteriepfand
7,50 EUR
incl. 19 % Tax excl. Shipping costs
stock: 995118
shipping time:: 2-4 business days (Ger)2-4 business days (Ger) (international delivery is divergent)
Motul 104025 MIN 100

Motor Oil 2T 4 Liter

Motul 104025 MIN 100
NBI 34,67 EUR
38,52 EUR
incl. 19 % Tax excl. Shipping costs
stock: out of stock
shipping time:: on requeston request (international delivery is divergent)
VPE: 9,63 EUR per liter
Athena S410210012009 26X33X4MM

Exhaust gasket S410210012009

Athena S410210012009 26X33X4MM
NBI 2,40 EUR
2,67 EUR
incl. 19 % Tax excl. Shipping costs
stock: 1000
shipping time:: 2-4 business days (Ger)2-4 business days (Ger) (international delivery is divergent)
Your Question

Type of request:
your name:
Your e-mail address:
Your question or comment:
Please answer the following question:
What color is grass?
your answer:

 
Customer reviews:

Author: Visitor

Your opinion:

CAUTION: HTML is not supported!

Evaluation:

Please answer the following question: 5+5-3 ?
your answer:

More Products in this Categorie:



Customer viewed this item have also viewed: